RCS WRIGHT FIELD TOOLS / RELEASE 0.1.3
THE HVAC TOOLBOX BUILD 0.1.3

Better airflow.
Smarter ductwork.

Start with unit tonnage, place supply takeoffs along the main trunk, and see exactly where trunk reductions are suggested as airflow is distributed to room registers.

Works in your browser No account required No data uploaded
DESIGN AIRFLOW1,000 CFM
ROOMS IN PLAN4 rooms
SUPPLY REGISTERS— registers
EST. CRITICAL SUPPLY PATH— in. w.c.

Room Airflow & Duct Planner

Working estimates for residential supply-air systems. Fill in system details, then your rooms and duct lengths.

i
Planning tool, not a Manual J / Manual D replacement. Tonnage does not establish room loads. Area-weighted CFM is only an initial distribution estimate. Manufacturer blower curves, actual room loads, fitting data, return duct design, register performance and field measurements are needed for final design.
01

System & airflow

Determine the total air available to distribute

Selecting a unit sets the listed default at 400 CFM/ton. You can edit the CFM to match the equipment's blower data or field measurements. Changing the unit resets CFM to its default.
02

Duct & pressure settings

Choose constraints and enter known blower pressure

Main supply trunk · enter existing dimensions
Default main supply trunk is 12 × 20 in. rectangular. Set dimensions to what is installed. When auto sizing is selected, the tool suggests a new main trunk size.
Branch duct shapes & sizing targets
Supply-pressure worksheet optional

Pre-filled loss allowances are illustrative placeholders; replace them with actual equipment and system data before using the budget.

03

Supply register sizing

Set register shape and dimensions for the whole job

Default is 4 × 12 in. rectangular. Selecting square uses a separate 12 × 12 in. default. Register sizes are nominal; actual rated free area varies by product.
04

Rooms & duct runs

Enter room size, registers, and branch lengths

Important: Enter the distance from the air handler to each room's takeoff on the main supply trunk. These positions tell the calculator where to subtract the room CFM and recommend a reduction. A blank takeoff position is estimated from room order. For complex branched trunks, model each trunk route separately.

Select round, square, or rectangular ducts and choose a suggested or entered existing branch size for each room and choose square or rectangular registers. Room CFM starts as a weighted share of system airflow. For a proper load-based design, enter each room's calculated CFM in Manual CFM.
ROOMSIZE / AIRFLOWDUCT RUN
05

Sizing results

Updates as you edit the worksheet

MAIN SUPPLY TRUNK
—
Enter your system data
SUPPLY PRESSURE BUDGETNot enteredRequires blower ESP
Room sizing scheduleBranches are sized per register, not for all registers combined

Designed for field planning.
Not false precision.

A

Room demand

Area weighting distributes a chosen system airflow. It does not calculate the building's cooling or heating load. Replace with room CFM from a qualified load design.

B

Duct resistance

Round and rectangular rigid galvanized duct losses are estimated using Darcy–Weisbach; non-round ducts use an approximate hydraulic diameter and a stated air-density/roughness assumption. Enter fitting equivalent lengths yourself. Flex duct, leakage and balancing are not modeled. Square and rectangular shapes are nominal dimensions; confirm actual installed dimensions.

C

Pressure budget

The main trunk is divided into sections at entered room takeoffs. Each section carries the remaining CFM and has its own estimated friction loss. A room path sums preceding trunk sections and one branch per register. Unknown fittings, pressure effects at takeoffs, supply transitions, returns and equipment must still be checked in the field.

D

Target versus delivered CFM

The number shown at each register is its target airflow, not predicted or measured delivery. The tool flags restrictive duct/register sizing, inadequate entered supply pressure, and unequal path resistance. Only verified blower, fitting and register performance followed by field balancing can establish actual delivered CFM.